Skip to main content

2024 | OriginalPaper | Buchkapitel

Robust Design of Smart Shorts for Muscle Activity Analysis

verfasst von : Teodorico Caporaso, Stanislao Grazioso, Alessia Megna, Antonio Lanzotti

Erschienen in: Design Tools and Methods in Industrial Engineering III

Verlag: Springer Nature Switzerland

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This paper describes a robust design approach to optimize the design of smart shorts for muscle activity analysis. A practical application related to electromyographic shorts for monitoring six main thigh muscles is shown. Starting from a 2D digital model of a pattern block related to the shorts, a robust design approach is applied to optimize the design of textile electrodes for surface electromyography analysis in terms of size (i.e., diameter), and location (i.e., inter-electrode distance). The aim is to reduce the sensitiveness to noise factors (i.e., skin lubrication condition, anthropometric variability and gesture type) guaranteeing the best performance in terms of Signal Noise Ratio. The experimental campaign related to football activities allows the practical application of the proposed approach for the design of smart shorts for football. The results allow to define the optimal configurations for the six muscles of interest. This work might pave the way for the development of tailored smart garments for electromyography analysis.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Taha, Z., Hassan, M.H.A., Majeed, A.P.P.A., Aris, M.A., Sahim, N.N., et al.: An overview of sports engineering: history, impact and research. Movement Health Exerc 2, 1–14 (2013)CrossRef Taha, Z., Hassan, M.H.A., Majeed, A.P.P.A., Aris, M.A., Sahim, N.N., et al.: An overview of sports engineering: history, impact and research. Movement Health Exerc 2, 1–14 (2013)CrossRef
2.
Zurück zum Zitat Caporaso, T., Grazioso, S., Di Gironimo, G., Lanzotti, A.: Design of wearables for biosignal acquisition: a user centered approach for concept generation and selection. In: Rizzi, C., Campana, F., Bici, M., Gherardini, F., Ingrassia, T., Cicconi, P. (eds.) ADM 2021. LNME, pp. 818–826. Springer, Cham (2022). https://doi.org/10.1007/978-3-030-91234-5_83CrossRef Caporaso, T., Grazioso, S., Di Gironimo, G., Lanzotti, A.: Design of wearables for biosignal acquisition: a user centered approach for concept generation and selection. In: Rizzi, C., Campana, F., Bici, M., Gherardini, F., Ingrassia, T., Cicconi, P. (eds.) ADM 2021. LNME, pp. 818–826. Springer, Cham (2022). https://​doi.​org/​10.​1007/​978-3-030-91234-5_​83CrossRef
3.
Zurück zum Zitat Caporaso, T., Grazioso, S., Di Gironimo, G.: Development of an integrated virtual reality system with wearable sensors for ergonomic evaluation of human-robot cooperative workplaces. Sensors 22(6), 2413 (2022)CrossRef Caporaso, T., Grazioso, S., Di Gironimo, G.: Development of an integrated virtual reality system with wearable sensors for ergonomic evaluation of human-robot cooperative workplaces. Sensors 22(6), 2413 (2022)CrossRef
4.
Zurück zum Zitat Valle, X.: Clinical practice guide for muscular injuries: epidemiology, diagnosis, treatment and prevention. Br. J. Sports Med. 45(2), e2–e2 (2011)CrossRef Valle, X.: Clinical practice guide for muscular injuries: epidemiology, diagnosis, treatment and prevention. Br. J. Sports Med. 45(2), e2–e2 (2011)CrossRef
5.
Zurück zum Zitat Lynn, S.K., Watkins, C.M., Wong, M.A., Balfany, K., Feeney, D.F.: Validity and reliability of surface electromyography measurements from a wearable athlete performance system. J. Sports Sci. Med. 17(2), 205 (2018) Lynn, S.K., Watkins, C.M., Wong, M.A., Balfany, K., Feeney, D.F.: Validity and reliability of surface electromyography measurements from a wearable athlete performance system. J. Sports Sci. Med. 17(2), 205 (2018)
6.
Zurück zum Zitat Colyer, S.L., McGuigan, P.M.: Textile electrodes embedded in clothing: a practical alternative to traditional surface electromyography when assessing muscle excitation during functional movements. J. Sports Sci. Med. 17(1), 101 (2018) Colyer, S.L., McGuigan, P.M.: Textile electrodes embedded in clothing: a practical alternative to traditional surface electromyography when assessing muscle excitation during functional movements. J. Sports Sci. Med. 17(1), 101 (2018)
7.
Zurück zum Zitat Aquino, J.M., Roper, J.L.: Intraindividual variability and validity in smart apparel muscle activity measurements during exercise in men. Int. J. Exercise Sci. 11(7), 516 (2018) Aquino, J.M., Roper, J.L.: Intraindividual variability and validity in smart apparel muscle activity measurements during exercise in men. Int. J. Exercise Sci. 11(7), 516 (2018)
8.
Zurück zum Zitat Farago, E., MacIsaac, D., Suk, M., Chan, A.D.C.: A review of techniques for surface electromyography signal quality analysis. IEEE Rev. Biomed. Eng. 16, 472–486 (2023)CrossRef Farago, E., MacIsaac, D., Suk, M., Chan, A.D.C.: A review of techniques for surface electromyography signal quality analysis. IEEE Rev. Biomed. Eng. 16, 472–486 (2023)CrossRef
9.
Zurück zum Zitat Si, X., Dai, Y., Wang, J.: Recognition of lower limb movements based on electromyography (EMG) texture maps. In: 2022 IEEE 5th International Conference on Electronics Technology (ICET), pp. 1091–1095. IEEE (2022) Si, X., Dai, Y., Wang, J.: Recognition of lower limb movements based on electromyography (EMG) texture maps. In: 2022 IEEE 5th International Conference on Electronics Technology (ICET), pp. 1091–1095. IEEE (2022)
10.
Zurück zum Zitat Grazioso, S., Selvaggio, M., Caporaso, T., Di Gironimo, G.: A digital photogrammetric method to enhance the fabrication of custom-made spinal orthoses. JPO: J. Prosthetics Orthot. 31(2), 133–139 (2019) Grazioso, S., Selvaggio, M., Caporaso, T., Di Gironimo, G.: A digital photogrammetric method to enhance the fabrication of custom-made spinal orthoses. JPO: J. Prosthetics Orthot. 31(2), 133–139 (2019)
12.
Zurück zum Zitat Tsui, K.-L.: An overview of Taguchi method and newly developed statistical methods for robust design. IIE Trans. 24(5), 44–57 (1992)CrossRef Tsui, K.-L.: An overview of Taguchi method and newly developed statistical methods for robust design. IIE Trans. 24(5), 44–57 (1992)CrossRef
13.
Zurück zum Zitat Ahad, M.A., Baidya, S., Tarek, M.N.: Comparison of circular and rectangular-shaped electrodes for electrical impedance myography measurements on human upper arms. Micromachines 14(6), 1179 (2023)CrossRef Ahad, M.A., Baidya, S., Tarek, M.N.: Comparison of circular and rectangular-shaped electrodes for electrical impedance myography measurements on human upper arms. Micromachines 14(6), 1179 (2023)CrossRef
14.
Zurück zum Zitat Solnik, S., Rider, P., Steinweg, K., DeVita, P., Hortobágyi, T.: Teager-kaiser energy operator signal conditioning improves EMG onset detection. Eur. J. Appl. Physiol. 110, 489–498 (2010)CrossRef Solnik, S., Rider, P., Steinweg, K., DeVita, P., Hortobágyi, T.: Teager-kaiser energy operator signal conditioning improves EMG onset detection. Eur. J. Appl. Physiol. 110, 489–498 (2010)CrossRef
15.
Zurück zum Zitat Park, S.H.: Robust design and analysis for quality engineering (1996) Park, S.H.: Robust design and analysis for quality engineering (1996)
Metadaten
Titel
Robust Design of Smart Shorts for Muscle Activity Analysis
verfasst von
Teodorico Caporaso
Stanislao Grazioso
Alessia Megna
Antonio Lanzotti
Copyright-Jahr
2024
DOI
https://doi.org/10.1007/978-3-031-58094-9_21

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.